Transmission Composite Supection-Tension Insulators in Silicone Rubber Type ROK-*class 160kN or class210kN

Transmission Composite Supection-Tension Insulators in Silicone Rubber Type ROK-*class 160kN or class210kN

Supection-Tension Insulators manufacturer


  • Product No.: Transmission Composite Supection-Tension Insulator

Details

 
 Transmission Composite Supection-Tension Insulators in Silicone Rubber Type ROK-*class 160kN or class210kN
Dimensions tolerance acc,to IEC61109
Selection Guide
(Line Voltage,kv)
Catalogue Code(◆) N°of Sheds A n°(1) Length L ±10 mm Leakage distance mm Minimnn arcing distance mm Power frequency withstand 50Hz Lightning impul. withstand 1,2/50 Weight~kg
72 123 145 170 250 400 Dry
kV
Wet 
kV
posit kV negat
.kV
            ROK-* 9+8 988 2375 778 275 195 460 495 4,4
            ROK-* 10+9 1072 2650 862 310 230 515 550 4,9
            ROK-* 12+11 1240 3200 1020 340 265 570 615 5,4
            ROK-* 14+13 1408 3100% 1198 380 300 620 670 5,9
            ROK-* 15+14 1492 4025 1282 415 335 670 725 6,4
            ROK-* 17+16 1660 4575 1450 450 370 720 780 6,9
            ROK-* 19+18 1828 5125 1618 485 405 770 835 7,4
            ROK-* 21+20 1996 5675 1786 520 435 830 900 7,9
            ROK-* 22+21 2080 5950 1870 565 475 915 990 8,4
            ROK-* 24+23 2248 6500 2038 615 515 1000 1080 8,9
            ROK-* 26+25 2416 7050 2206 645 545 1070 1155 9,4
            ROK-* 27+26 2500 7325 2274 675 575 1140 1230 9,7
            ROK-* 29+28 2668 7875 2458 710 605 1210 1310 10,4
            ROK-* 31+30 2836 8425 2626 760 640 1270 1370 10,9
            ROK-* 33+32 3004 8975 2784 810 675 1330 1430 11,4
            ROK-* 35+34 3172 9525 2962 860 710 1390 1490 11,9
            ROK-* 36+35 3256 9800 3046 875 720 1450 1565 12,4
            ROK-* 38+37 3424 10350 3214 890 740 1520 1640 12,9
            ROK-* 40+39 3592 10900 3382 905 100% 1585 1715 13,4
            ROK-* 42+41 3760 11450 3550 920 760 1650 1800 13,9
NOTE:Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,in order to obtain    the total length of the insulator(L),please select the kind of fitting end you have to use and refer to the following table:
Ground fitting Line fitting Code(2) Length
change(L)
SOCKET BALL SB 0
CLEVIS TONGUE CT -40
EYE EYE EE +55
EYE BALL EB +20
EYE TONGUE ET +5
CLEVIS BALL CB -25
SOCKET EYE SE +30
Y-CLEVIS TONGUE YT +5
Y-CLEVIS EYE TE +50
  Specified Mechanical Load      SML-IEC61109
Routine Test Load          RTL=50%of SML
Specified Mechanical Load      160kN   210kN
Routing Test Load          80kN    105kN
Max.torsion Load           120N*m   120N*m
The metal fittings are in galvanized steel
(◆)Key to the catalogue numbers
*Key:ROK-A(1)-(160 or 210)(2)
Example:ROK-A22+21-(160 or 210)SB
Please don’t hesitate to contact us directly for obtaining possible explanations or different solutions.
These insulators are produced and tested according to IEC61109. It’s possible to have all the other combinations.

· Transmission Composite Supection-Tension Insulators in Silicone Rubber Type SOR-*class 300kN
Dimensions tolerance acc,to IEC61109
,
Selection Guide
(Line Voltage,kv)
Catalogue Code(◆) N°of Sheds A n°(1) Length L ±10 mm Leakage distance mm Minimnn arcing distance mm Power frequency withstand 50Hz Lightning impul. withstand 1,2/50 Weight~kg
115 145 170 345 420 500 Dry
kV
Wet 
kV
posit kV negat
.kV
            SOR-* 7+6+6 916 1920 628 350 275 580 625 3.6
            SOR-* 9+8+8 1082 2560 844 3850 300 620 670 4.4
            SOR-* 11+10+10 1248 3200 1010 415 335 670 725 5.2
            SOR-* 13+12+12 1414 3840 1176 455 375 725 785 6.1
            SOR-* 15+14+14 1580 4480 1342 480 400 765 830 6.9
            SOR-* 17+16+16 1746 5120 1508 525 440 840 910 7.8
            SOR-* 19+18+18 1912 5760 1674 570 480 920 995 8.6
            SOR-* 21+22+22 2078 6400 1840 610 510 990 1070 9.5
            SOR-* 23+22+22 2244 7040 2006 645 545 1050 1155 10.3
            SOR-* 25+24+24 2410 7680 2172 685 585 1150 1240 11.1
            SOR-* 27+26+26 2576 8320 2338 700 595 1200 1300 12.0
            SOR-* 29+28+28 2742 8960 2504 740 620 1250 1350 12.8
            SOR-* 31+30+30 2908 9600 2670 815 660 1340 1440 13.7
            SOR-* 33+32+32 3074 10240 2836 845 685 1380 1480 14.5
            SOR-* 35+34+34 3240 10880 3002 865 710 1485 1585 15.4
            SOR-* 37+36+36 3406 11520 3168 900 100% 1670 1820 16.2
            SOR-* 39+38+38 3572 12160 3334 930 780 1760 1860 17.0
            SOR-* 41+40+40 3738 12800 3500 960 820 1780 1930 17.9
            SOR-* 43+42+42 3904 13440 3666 1140 1020 2030 2110 18.7
            SOR-* 47+46+46 4236 14720 3998 1280 1100 2400 2510 19.5
NOTE:Once chosen the insulator that is the most suitable to the characteristics of the line on which you have to install it,in order to obtain    the total length of the insulator(L),please select the kind of fitting end you have to use and refer to the following table:
Ground fitting Line fitting Code(2) Length
change(L)
SOCKET BALL SB 0
CLEVIS BALL CT 0
SOCKET TONGUE ST 0
CLEVIS TONGUE CT 0
  Specified Mechanical Load      SML-IEC61109
Routine Test Load          RTL=50%of SML
Specified Mechanical Load      300kN  
Routing Test Load          155kN 
Max.torsion Load           200N*m
The metal fittings are in galvanized steel
(◆)Key to the catalogue numbers
*Key:SOK-A(1)-(300)(2)
Example:OK-A21+20-300SB
Please don’t hesitate to contact us directly for obtaining possible explanations or different solutions.
Socket and ball are size 24 acc.To IEC60120 Clevis and tongue are size 25 Lacc.To IEC60471
These insulators are produced and tested according to IEC61109. It’s possible to have all the other combinations.